<?xml version="1.0" standalone="yes"?>
<?xml-stylesheet type="text/xsl" href="..\..\XSLTemplates\NVSStyleSheet.xsl"?>
<Parameter>
<ParameterFamily>gc</ParameterFamily>
<LongName>
sscan_shift_adjust
</LongName>
<Name>
sssa
</Name>
<AppliesTo>
<UnnumberedList>
<ListItem><TextApplies>Green</TextApplies></ListItem>
<ListItem><TextApplies>HRX</TextApplies></ListItem>
</UnnumberedList>
</AppliesTo>
<Description>
<DescriptionText><text>
Adjusts the image position in the subscan (head travel) direction.  This
parameter is calibrated during factory integration and normally should not
change after this.  Adjustments should be made either with advice from factory
integrators or with the special plate registration measuring jig.
</text></DescriptionText>
<DescriptionText><text>
Make this parameter larger (more positive) to shift the image away from the
plate's edge detect edge.
</text></DescriptionText>
</Description>
<Type>
real
</Type>
<Default>
<UnnumberedList>
<li>0</li>
</UnnumberedList>
</Default>
<Range>
<UnnumberedList>
<li>-44000.0 to 44000.0 [mils]</li>
</UnnumberedList>
</Range>
<ArraySize>
</ArraySize>
<Notes>
<DescriptionText><text>
</text></DescriptionText>
</Notes>
<Partition>
cal
</Partition>
<SeeAlso>
<UnnumberedList>
<li><Link><LinkAddress>../nvs/gc_cfg_sss.xml</LinkAddress><LinkTitle>NVS: gc sss</LinkTitle></Link></li>
<li><Link><LinkAddress>../nvs/mode_cal_sssa.xml</LinkAddress><LinkTitle>NVS: mode sssa</LinkTitle></Link></li>
</UnnumberedList>
</SeeAlso>
<OtherLinks>
<li><Link><LinkAddress>..\..\ShowAllErrors.htm</LinkAddress><LinkTitle>Firmware 0 Error Index</LinkTitle></Link></li>
<li><Link><LinkAddress>..\..\ShowAllCommands.htm</LinkAddress><LinkTitle>Firmware 0 Command Index</LinkTitle></Link></li>
<li><Link><LinkAddress>..\..\ShowAllNVS.htm</LinkAddress><LinkTitle>Firmware 0 NVS Index</LinkTitle></Link></li>
</OtherLinks>
<Updated>
Updated: Wed Jul 16 19:36:49 2008 PST
</Updated>
<Links>
</Links>
</Parameter>